  t-Rex 3200 I-44-89 L12 S2 DH
Rated voltage Rated current
Rated torque
Rated speed
Shaft power (output) Max. efficiency
Idle speed
No-load current
Stall torque
Starting current at idle speed Torque constant
Speed constant
Motor parameters
Terminal resistance (phase to phase) Terminal inductance (phase to phase) Rotor inertia
Number of poles
Interconnection of the motor Number of coils per phase Interconnection of coils Direction of rotation
Note: Max. ambient temperature = 40 °C, controller-specific At the nominal point (TU = 20°C), controller-specific
Motor characteristics at 24 V
S1 Mode
3200.00-0004
24 VDC 4.0 A
0.3 Nm 2418 rpm 67 W 74 %
2680 rpm
0.55 A
2 Nm 22.7 A 0.09 Nm/A 112 rpm/V
36 VDC 4.0 A
0.2 Nm 3767 rpm 79 W 76 %
4053 rpm
0.56 A
2 Nm 21.6 A 0.09 Nm/A 113 rpm/V
                                        27 Ohm
45 mH
26.5 kg* mm2
14
Star
2
2 Series
bidirectional
                 Motor phases
97531
10 8 6 4 2
1= U-Phase 2= n.c.
3= U-Phase 4= U-Phase 5= V-Phase 6= V-Phase 7= W-Phase 8= V-Phase 9= W-Phase
     Torque (Nm)
Socket strip RM 2.54 / 8 PIN W+P 3491-08
Digital Hall-sensors
Supply of sensors: Voltage range: 4.5 to 5.5 V DC / Optional: voltage regulator for 5 V, Input current: < 70 mA Output signals of sensors: Differential output (RS422 standard, datasheet AM26 C31-TI)
Typical voltage range: 0.2/ 3.4 V @ 20 mA, Output current: max. 20 mA
Signal structure: The Hall sensors have a 120° phase shift to each other. Due to the 14-pole design the Signal frequency is seven times higher than the speed
10= W-Phase n.c.= please do not connect
RM 2,54 / 10 PIN W+P 3491-10
Hall-sensors
 2468
1357
1= H3- 2= H1- 3= 5 V 4= H3+ 5= H1+ 6= GND 7= H2+ 8= H2-